Why Do VELUX Windows Leak?
The short answer
VELUX windows usually leak at the junction with the roof, not through the glass. The commonest causes are flashing that has lifted or corroded, seals that have hardened with age, condensation that looks like a leak, and roof covering that has slipped around the frame. A well-fitted roof window should stay dry for many years, so a leak is a sign that something around it has changed. Finding which cause applies is the first step, and it decides whether the unit needs replacing.
Where the water in your loft room really comes from.

Flashing and the junction with the roof
Flashing is the metalwork that ties the window into the tiles or slates and leads rain around the frame. Over the years it can lift at an edge, corrode, split at a corner or be disturbed by movement in the roof covering. Water then tracks beneath it and finds its way down the frame.
The signs are a stain that appears on the lining at one side or at the lower corner, usually after heavy or wind-driven rain. Flashing is cut for one window size, so a mismatched or carelessly fitted kit invites water. When a window is replaced, new flashing is part of the job for exactly this reason.
Tiles and slates nearby
The covering above and beside the window matters just as much. A cracked tile or a slipped slate directly above the frame can send water straight at the junction. What looks like a failed window may turn out to be a fault in the covering next to it, which is why the roof is checked as well as the window.
Condensation that looks like a leak
Many reported leaks turn out to be condensation. Roof windows sit in a cold plane of the roof. Warm, moist air from a bathroom, a bedroom or a kitchen meets the cold glass and frame and turns to water, which runs down and can soak the lining. The marks look the same as a leak, but they appear on cold mornings rather than after rain.
Condensation points to a ventilation problem more than a window problem. A window that can be opened a little to a venting position helps clear moist air. Extractor fans in bathrooms and kitchens, and a gap between the window and any blind, also help. If the glass is misted between the panes, though, the sealed unit has failed and the glass cannot be cleared, which is a case for replacement.
A true leak against condensation
True leak
- Shows after rain or wind
- Staining at one edge or corner
- Damp even on warm days
- Often tracks from the flashing
Condensation
- Shows on cold mornings
- Water beads on the glass
- Worse after showers or cooking
- Clears when the window is vented
Seals, frames and age
Rubber and foam seals harden over time and lose their grip. Frames, especially timber ones, can weather and move. A sash that no longer closes tight lets in air and, in driving rain, water. Older units also suffer from failed sealed glass units, which mist and lose efficiency, although this is a loss of insulation rather than a leak.
If the frame has softened or the seals have given up, the unit is often beyond repair and a replacement is the sensible route. What a swap involves, including new flashing and the lining made good, is set out in the replacement guide.
Installation faults
A window that has leaked since the week it was fitted points to the installation. A frame fixed out of square, flashing laid in the wrong order or a missing tilting fillet can all allow water in. These faults do not improve with time. They argue for an installer who builds the junction carefully and backs it in writing; our workmanship guarantee runs for 10 years.
What to do when you see a stain
Start by working out when the water appears. After rain suggests the flashing or covering. On cold mornings suggests condensation. If it follows both, there may be two causes together.
Photograph the stain and the window from inside, and note which edge it is nearest. If you can see the roof safely from the ground or from an upper window, look for slipped tiles or lifted metal near the frame, but do not climb onto the roof. Check the loft timbers beneath the window for dampness, which shows a leak has been running for some time.
Then book a survey. We examine the roof, the window and the loft, and report where water is getting in and whether the unit needs replacing. The quote is written with a fixed figure. Fill in the survey form or send a WhatsApp to 07880 284133. The VELUX section gives the wider picture, and if several windows are tired, a set done together may suit.
Leaking roof window queries
Is a leaking roof window always the window's fault?
No. Water near a window often comes from the flashing, from a slipped tile or slate beside it or from condensation. The window itself is sound in many such cases. A survey of the window, covering and loft separates these causes so that the right part is dealt with.
Why does my window drip only in winter?
That pattern usually means condensation. Warm, damp indoor air meets cold glass and turns to water, which runs down the frame. Better ventilation, an extractor fan in wet rooms and using the venting position on the sash all help clear it.
Can new flashing alone cure a leak?
It can when the flashing is the only fault. A replacement kit matched to the window is fitted with the covering lifted back around the frame. If the frame or seals are also tired, replacing the whole window is usually the better step.
How do I know the sealed glass has failed?
Mist or droplets between the two panes that do not wipe off mean the seal has failed. The glass no longer insulates properly. That is a different fault from a leak, and the sealed unit or the full window is replaced.